Power transformer testing and commissioning guidelines r 1. Sp0507r01 current transformer testing job safety analysis. Basics, maintenance, and diagnostics xi contents continued page 9. Transformer precommissioning tests and afterreceipt checks you. The commissioning and maintenance personnel must be well experienced in using protection equipment, test equipment, protection. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. Testing power transformers highvoltage transformers are some of the most important and expensive pieces of equipment required for operating a power system. These tests are done to assess the condition of transformer after installation and compare the test results of all the low voltage tests with the factory test reports. The noload loss and current measurements of a transformer are made while one of the windings usually the hv winding is kept open and the other winding is supplied at the rated voltage and frequency. Tm 5686 power transformer maintenance and acceptance.
Testing and commissioning of current transformer free download as pdf file. Testing of power transformers seems like a similar experience. Power transformer testing and commissioning guidelinesoil. This practical commissioning test was developed decades ago and the authors are simply presenting the theory and procedure of how the test performs in the substation. Transformer should be inspected by authorized electrical inspector and get permission to energize the same 2. Current transformers shorting block to prevent open circuiting the current transformers shall also be tested. All materials and relevant documentation to this testing works shall be checked by the responsible personnel prior to the commencement of testing activities.
A primary part of commissioning a transformer involves testing it after its installation in the field. Testing and commissioning of current transformer scribd. Based on the microprocessor protective relays manual, a minimum secondary current of 0. Transformer installation method statement electrical. For dry type transformers, the insulation system consists of the cast resin winding and core insulation. All transformers are subjected to the following pre commissioning tests. Instrument transformers for metering purposes must have a high degree of accuracy up to class 0. On subtractive polarity transformers the h1 primary lead and the x1 secondary lead will be on the same.
The basics of current transformers nk technologies. Power transformer testing and commissioning guidelinesr sahoo procedure of power transformer testing and commissioning in transformer testing and commissioning, it can be classified into power and distribution transformers. The transformer has been built to standard damage has not been sustained during transit or installation. Site testing will be carried out to the mv transformer by the authority approved testing contractor and to be witness by authorities, consultant and contractor.
Drytype transformer testing introduction the primary concern with all transformers and also the key indicator of life expectancy is the condition of the insulation system. You can repeat the procedure above for each tap of a multi. Along with different precommissioning tests, different instruments associated to the transformer also to be checked. Repeat the test for the other phases and the other secondary cores. Hence, it is essential to inspect and calibrate those instrument transformers at regular intervals. Introduction the procedures stated in this document cover the activities in preliminary tests and inspections, functional performance tests and the commissioning of newly completed installations and existing ones after major alteration. Perform insulationresistance tests of the current transformer and. Connection on cpc100 will be same as the shown figure. Various electrical tests must be performed and their significance and short description are given below.
Testing and commissioning procedure for electrical installation 1. Transformer is the most important equipment in the electrical power transmission and distribution system. Potential voltage transformers testing and precommissioning check potential voltage transformers can be broadly divided in to two type. Instrument transformer theory and testing steve hudson, pe engineering manager 10737 lexington drive knoxville, tn 37932 phone. Commissioning procedure of power transformer in transformer testing it can be classified into power and distribution transformers. Testing and commissioning is the last point in the past when a project is a fact and all of the equipment is subjected to preenergizing field tests in accordance with the procedures, the electrical devices are put into operation and the system is put into operation. Losses of transformersthe transformers are made of 2 types of materials. All works prior to testing location to be barricaded and for precautionary safety measure. Use small jumper to short the ct secondary from ct box, the measurement will be gone at panel.
It rating plate show nominal voltage, current of primary and secondary voltage at various of the tap changer, connection symbols vector group, % impedance weight of oil etc. Voltage transformers testing and commissioning guidelines. In addition some other tests are also carried out by the consumer at site before commissioning and also. In this test we confirm the ct secondary connection.
The pre commissioning test result should to compare with manufacture test result basically on transformer name plate or manual guideline and international standard ieee standard or interplant standardsteel industry, code of practice for testing and commissioning of power transformer and related switchgears, ipss. From diagnostics to consulting to recommendations for action as well as technical implementation, we provide a onestop source for everything you need. Mainly two types of transformer are done by manufacturer before dispatching the transformer mainly 1 type test of transformer and 2 routine test. Transformer routine test measurement of noload loss and. Purpose and scope the purpose of this standard work practice swp is to.
Stability of differential, ref of transformer reactor. Distribution commissioning test sheet non mps distribution transformer hpc4dl0700212014 this commissioning test sheet covers the checking, testing and commissioning of all replacement or new installations of nonmodular package substation nonmps groundmounted transformers up to 1,000 kva before energisation. The need for a comprehensive current transformer testing regime is evident when the alternative is considered. Pdf transformer testing type test and routine test of. This amounts to a rigorous examination of the transformer intended to. It evolved from the simple gonogo verdict into a sophisticated segment within transformer manufacturing. The transformer testing performed before commissioning the transformer at the site is called the precommissioning test of transformer. Page 1 of 9 standard work practice sp0507 ver 5 ergon energy corporation limited abn 50 087 646 062 ergon energy queensland pty ltd abn 11 121 177 802 1. Ir values a for 3311 kv power transformer 2500 v megger is to be need. These can be of electromagnetic of capacitive voltage transformer type cvt. The commissioning personnel must have a basic knowledge of handling electronic equipment. Current transformer testing swp check this is the latest process zone version before use.
There are various test required on transformer to conform performance of transformer. Commissioning of distribution transformer before actually charging the transformer the following points should be checked. The purchase, preparation, assembly, operation and maintenance of transformers represent a large expense to the power system. Maximum reliability and availability of your power transformers that is what we work towards.
A presentation ontransformer testing using dpatt3bi 2. Powersystems requirements for electrical testing of hv. Measurement of no load loss and current open circuit test. Power transformer testing and commissioning guidelines r. Transformer bushing cts should be tested using the current ratio test method. Transformer testing commissioning, routine, diagnostic.
Power transformer best during this test the noload current. Back to the basics current transformer ct testing valence. Transformers while experiencing severity of short circuit current looses its mechanical property by way. Testing and commissioning instrumenttransformers free download as powerpoint presentation.
A fault leading to an open secondary could cause the primary current to overwhelm the. Commissioning test for power transformer biology essay. Insulation resistance and continuity of the winding should be checked by v megger 3. Pre commissioning of power transformer engineering essay. Ensure the ct is connected to system properly in all respect primary and secondary. Transformer pre commissioning tests and afterreceipt checks you. Prior to start of terminations this is to ensure that the transformer are in a defect free state. The transformer testing performed before commissioning the transformer at site is called. This method statement will give a brief steps to be carried out for testing and pre commissioning of transformers. In order to ensure availability of uninterrupted power supply, it is essential that the condition of transformer is continuously monitored during service as failure of transformer would result in interruption of power supply resulting loss of industrial production.
The power transformer testing performed before actual commissioning test of the transformer at site is called pre commissioning of the power transformer at site like insulation resistance test, transformer turns ratio test, dc winding resistance test, temperature test and oil test2. Transformer routine test measurement of noload loss and current on photo. Transformer testing type tests and routine tests of. In this book we have laid down important aspects on transformer. Testing will commence only after the equipment is completely installed as per approved method statement for the installation of the transformer and released for testing commissioning. The usual procedure is for the person operating the battery connections to. Current transformers play an important role in the monitoring and protection of electrical power systems. After, installation of power transformer, several precommissioning tests to be done before putting the transformer in service. The core of a transformer is made of iron whereas thewinding which is wrapped over the iron core is made up ofcopper. To confirm the physical condition and electrical characteristics of current transformer installed in the installation. Transportation, erection, testing and commissioning ieema. There are various test required on transformer to conform.
Polarity refers to the instantaneous direction of the primary current with respect to the secondary current and is determined by the way the transformer leads are brought out of the case. A routine series of diagnostics and testing for your current transformer should include ct saturation testing to identify the knee point against ieee or iec standards, ct ratio tests to identify that the voltage ratio is within expected parameters and current transformer resistance testing for both the transformer windings and ct insulation. Transformer testing has developed considerably over the past years. Transformer precommissioning tests and afterreceipt. To the precommissioning checks required for new primary transformers, each. Neta is not only for commissioning new equipment but for testing the reliability and performance of existing equipment. Disconnect all power prior to testing and connect the analog voltmeter to the secondary terminal of the ct to be. Cts are instrument transformers used for converting primary current into a reduced secondary current for use with meters, relays, control equipment and other instruments the importance of instrument transformer tests is often underestimated. Before commencement of any test make sure the surroundings near clear off from any. Hv tests can be selected as a proven method for commissioning, diagnosis and final acceptance of new and repaired or even refurbished power transformers. Scribd is the worlds largest social reading and publishing site.